A Study on Implementing Physiology-Based Approach and Optical Flow Algorithm to Thermal Screening System for Flu Detection
Keywords:
Infrared, optical flow algorithm, physiology-based approach, thermal image processing.Abstract
Viral outbreaks such as SARS, H5N1, and H1N1
have led the need of temperature monitoring in areas where crowds are expected such as in hospitals and airports. Infrared (IR) thermal screening, hitherto, has been found as powerful, quick and non-invasive method to detect the elevated temperature of febrile individuals when the temperature of the face is above 36°. Past research has proved that the most excellent area that represents the core body temperature is the medial canthal areas of the face as it is less dependent on the
effects of ambient temperature. In realistic situation, the moving subjects are random and the angles of the skin surface and distances change dynamically and misdetection of canthal area could also be due to any other unwanted objects that have the same temperature. The normal approach is to ask a single
person to stand still for 2 seconds to capture the temperature. However this approach is ineffective and this will lead to long queue in public. To solve this issue, we have proposed a combination of physiology-based and optical flow algorithm to extract vascular network from the face. The thermal camera is provided with colour and audible alarming, hence when the
camera detect an abnormal temperature from a person, automatic febrile individual tracking alarm will report to the operator the current location of the individual.
Downloads
Downloads
Published
Issue
Section
License
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation .
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.