Abstract

The input power to an induction motor is in the 
form of three phase electric voltages and currents. The first 
losses encountered in the machine are I2R losses in the stator 
winding. The stator copper loss occurs when the stator 
windings is energized. This can be reducing by increasing the 
stator slot size. This paper present the investigation on the 
stator copper loss effect between two different stator slot size 
which is 6mm and 8mm using 2D Finite Element Analysis (2D
FEA), model of 0.5hp induction motor. 